Vertical HVAC liquid receiver for refrigeration and air conditioning systems

Durable Liquid Receiver for HVAC & Industrial Refrigeration (Vertical/Horizontal)

High-Quality Vertical Refrigerant Receiver Tanks

Our HVAC liquid receivers, also known as refrigeration liquid receivers or refrigerant receiver tanks, are designed to store liquid refrigerant in refrigeration and air conditioning systems. Installed after the condenser, the liquid receiver ensures that a stable supply of liquid refrigerant is delivered to the expansion device while allowing the system to operate efficiently under varying load conditions.

KAK manufactures high-quality vertical liquid receivers for commercial HVAC equipment, refrigeration systems, heat pumps, and industrial cooling applications. Our receivers are designed with durable construction, reliable sealing, and flexible connection options to meet different system requirements.

Product Overview

A liquid receiver is an essential component in refrigeration systems. It stores liquid refrigerant leaving the condenser and maintains adequate refrigerant supply to the expansion valve. During maintenance or system load changes, the receiver also provides temporary refrigerant storage, helping ensure stable system performance.

Our receivers are typically supplied in a vertical configuration, with connection ports designed for easy installation in HVAC and refrigeration equipment. Additional accessories such as sight glass, support feet, and safety valve connections can be provided depending on the application.

Main Features

  • Designed for HVAC and refrigeration systems
  • Stores liquid refrigerant from the condenser
  • Ensures stable liquid refrigerant supply to expansion devices
  • Vertical & Horizontal Configurations: While our standard vertical liquid receivers are optimized for compact equipment layouts, we also provide horizontal HVAC receivers for systems with height restrictions, such as rooftop units or under-chassis refrigeration systems.
  • Multiple connection sizes available
  • Optional fittings such as sight glass and safety valve connection
  • PTFE sealing gasket for reliable sealing performance
  • High-corrosion-resistant coating finish
  • Compatible with common refrigerants and refrigeration oils
  • Custom receiver sizes and configurations available

Typical Applications

  • Commercial air conditioning systems
  • Refrigeration condensing units
  • Cold storage refrigeration systems
  • Heat pump systems
  • Industrial refrigeration equipment
  • Water chillers
  • Marine refrigeration applications

Technical Features

  • Structure: Vertical liquid receiver
  • Connection type: ODF copper connection
  • Seal: PTFE sealing gasket
  • Max allowable working pressure: 40 bar
  • Burst pressure: 190 bar
  • Working temperature range: -40°C to 100°C
  • Compatible refrigerants: HFC, HCFC, CFC and related refrigeration oils

Installation & Orientation Flexibility

Our receiver series is engineered for versatile installation. While vertical configurations are our most popular standard, our horizontal HVAC receivers feature specialized internal dip tubes to ensure a consistent liquid seal.

This design prevents vapor bypass and ensures stable refrigerant flow even in low-profile installations or mobile refrigeration applications.

Customization Options

We provide OEM and custom manufacturing services for HVAC liquid receivers. Receiver volume, connection size, pressure rating, coating finish, and structural design can be customized according to system requirements.

  • Custom receiver volume
  • Custom connection sizes
  • Custom pressure ratings
  • Optional surface coatings
  • OEM production based on drawings
+ Click to view KAK-CLR Series (1.1L – 14L) Specifications
TPLC Vertical Liquid Receiver 1.1L-14L
Model No.ODF Conn. (in)ΦD (mm)H (mm)H1 (mm)H2 (mm)A (mm)Volume (L)
KAK-CLR-1013/8"8919413240401.1
KAK-CLR-1023/8"12725818140402.8
KAK-CLR-1033/8"12728920440403.9
KAK-CLR-1041/2"15934827740406.3
KAK-CLR-1055/8"16541432045458
KAK-CLR-1063/4"165600510454512
KAK-CLR-1077/8"165700610454514
+ Click to view KAK-CLRW Series (1L – 21L) High-Density Models
TPLC Vertical Liquid Receiver 1L-21L
Model No.ODF Conn. (in)ΦD (mm)H (mm)H1 (mm)A (mm)Volume (L)Schematic
KAK-CLRW-1333/8"10218040451a
KAK-CLRW-2333/8"12719540502a
KAK-CLRW-3333/8"12731040503a
KAK-CLRW-4333/8"16524540554a
KAK-CLRW-6441/2"16533040556a
KAK-CLRW-8441/2"16541540558a
KAK-CLRW-10555/8"219310457510b
KAK-CLRW-12555/8"219370457512b
KAK-CLRW-14555/8"219430457514b
KAK-CLRW-16777/8"219489507516b
KAK-CLRW-18777/8"219549507518b
KAK-CLRW-21777/8"219610507521b
+ Click to view KAK-VLR Series (50L – 800L) Industrial Receivers
DNBL Industrial Vertical Liquid Receiver
Model No.Inlet (BW)Outlet (BW)Safety ValveService ValveΦD (mm)H (mm)H1 (mm)H2 (mm)H3 (mm)YxY (mm)ΦG (mm)ΦZ (mm)Volume (L)
KAK-VLR-50Φ38Φ321/2" NPT"3/8" NPT"27310631556501551933001250
KAK-VLR-80Φ38Φ321/2" NPT"3/8" NPT"32511951847001842303501380
KAK-VLR-100Φ45Φ381/2" NPT"3/8" NPT"377115520660020626742013100
KAK-VLR-150Φ57Φ451/2" NPT"3/8" NPT"402143521090021029045014150
KAK-VLR-200Φ57Φ451/2" NPT"3/8" NPT"462142824480024432749014200
KAK-VLR-250Φ76Φ571/2" NPT"3/8" NPT"4621788244110024432749014250
KAK-VLR-300Φ76Φ571/2" NPT"3/8" NPT"5121762266100026636054018300
KAK-VLR-400Φ76Φ571/2" NPT"3/8" NPT"5621918300110030039059018400
KAK-VLR-500Φ76Φ573/4" NPT"3/8" NPT"6122012310120031042564018500
KAK-VLR-600Φ76Φ573/4" NPT"3/8" NPT"6662072324120032446570018600
KAK-VLR-800Φ89Φ763/4" NPT"3/8" NPT"7162344334140033449775018800
+ Click to view KAK-HLR Series (50L – 10000L) Horizontal Receivers
DNBW Industrial Horizontal Liquid Receiver
Model No.Inlet (BW)Outlet (BW)Safety ValveDraining PlugΦD (mm)H (mm)H1 (mm)L (mm)L1 (mm)L2 (mm)L3 (mm)L4 (mm)ΦZVolume (L)
KAK-HLR-50Φ38Φ321/2" NPT1-1/4"-12UNF273483150986600640801802050
KAK-HLR-80Φ38Φ321/2" NPT1-1/4"-12UNF32553515011126007001002102080
KAK-HLR-100Φ45Φ381/2" NPT1-1/4"-12UNF377587150106860063010025020100
KAK-HLR-150Φ57Φ451/2" NPT1-1/4"-12UNF402612150135282090010026020150
KAK-HLR-200Φ57Φ451/2" NPT1-1/4"-12UNF462672150134880076015029020200
KAK-HLR-250Φ76Φ571/2" NPT1-1/4"-12UNF46271215016581100107015029020250
KAK-HLR-300Φ76Φ571/2" NPT1-1/4"-12UNF46271215019781100139015029020300
KAK-HLR-400Φ76Φ571/2" NPT1-1/4"-12UNF56281215017881100115015036020400
KAK-HLR-500Φ76Φ573/4" NPT1-1/4"-12UNF61286215018821050122015040020500
KAK-HLR-600Φ76Φ573/4" NPT1-1/4"-12UNF61286215022321200157015040020600
KAK-HLR-800Φ89Φ763/4" NPT1-1/4"-12UNF71696615022161200150015046020800
KAK-HLR-1000Φ89Φ761" NPT1-1/4"-12UNF7161016200273420001650160460201000
KAK-HLR-1500Φ89Φ761" NPT1-1/4"-12UNF8161116200313623001785300530201500
KAK-HLR-2000Φ89Φ761" NPT1-1/4"-12UNF9161216200331624001900300590202000
KAK-HLR-2500Φ108Φ891" NPT1-1/4"-12UNF10201320200337023501800300600242500
KAK-HLR-3000Φ108Φ891" NPT1-1/4"-12UNF10201320200401030002370300600243000
KAK-HLR-3500Φ108Φ891" NPT1-1/4"-12UNF11201420200389026802120300660243500
KAK-HLR-4000Φ108Φ891" NPT1-1/4"-12UNF11201420200442032002550400660244000
KAK-HLR-5000Φ108Φ891" NPT1-1/4"-12UNF12241524200464433002700400720245000
KAK-HLR-6000Φ108Φ891" NPT1-1/4"-12UNF12241524200553442003580400720246000
KAK-HLR-7000Φ108Φ891" NPT1-1/4"-12UNF14241724200477433402720400840247000
KAK-HLR-8000Φ108Φ891" NPT1-1/4"-12UNF14241724200545440203410400840248000
KAK-HLR-10000Φ108Φ891" NPT1-1/4"-12UNF152818782505948420036604509002410000

FAQ

What is the function of a liquid receiver in an HVAC system?

A liquid receiver stores liquid refrigerant leaving the condenser and ensures that only liquid refrigerant enters the liquid line and expansion device. It also provides refrigerant storage during system load changes or maintenance.

What refrigerants are compatible with the liquid receiver?

Our receivers are compatible with common refrigerants such as R22, R134a, R407C, R410A, R404A, and other commonly used refrigerants together with their refrigeration oils.

What is the maximum allowable working pressure?

The maximum allowable working pressure is 40 bar with a burst pressure of 190 bar. Custom pressure ratings can be designed according to system requirements.

Are horizontal HVAC liquid receivers available?

Yes. While we specialize in vertical liquid receivers, we offer a full range of horizontal models for projects with limited vertical clearance. These are commonly used in marine refrigeration, transport cooling, and rooftop HVAC units.

All horizontal units maintain the same 40 bar working pressure rating and PED/CE compliance as our vertical series, ensuring high reliability for industrial applications.

What information is required to select a suitable liquid receiver?

To recommend a suitable model we usually need the refrigerant type, system capacity, receiver volume requirement, connection size, operating pressure, and installation space limitations.

Can the liquid receiver be customized?

Yes. Volume, dimensions, connection size, coating, and structural design can be customized according to customer specifications.

Related HVAC & Refrigeration Components